Effect of Signal Filtering on Image Quality of Projection-Based Magnetic Particle Imaging

Shimada, Kazuki and Murase, Kenya (2017) Effect of Signal Filtering on Image Quality of Projection-Based Magnetic Particle Imaging. Open Journal of Medical Imaging, 07 (02). pp. 43-55. ISSN 2164-2788

[thumbnail of OJMI_2017060711362378.pdf] Text
OJMI_2017060711362378.pdf

Download (1MB)
[thumbnail of OJMI_2017060711362378.pdf] Text
OJMI_2017060711362378.pdf - Published Version

Download (1MB)

Abstract

Purpose: Magnetic particle imaging (MPI) allows for imaging of the spatial distribution of magnetic nanoparticles (MNPs) in positive contrast, with high sensitivity, high spatial resolution, and high imaging speed. It is necessary to increase the signal-to-noise ratio to enhance the reliability of MPI. The purpose of this study was to investigate the effect of signal filtering on the image quality and quantitativity in projection-based MPI using phantoms. Materials and Methods: We fabricated two kinds of phantom (cylindrical tube phantom with a diameter of 6 mm and A-shaped phantom) and evaluated the effect of signal filtering in terms of root-mean-square (RMS) granularity and the correlation coefficient between iron concentrations of MNPs and average MPI values for four filter modes (THRU, BPF, BEF, and LPF). In the THRU mode, the signal input was output without passing through the filter. In the BPF mode, only the third-harmonic signal was passed using a band-pass filter (central frequency: 1200 Hz, band width: 1/3 octave). In the BEF mode, the first-harmonic signal was eliminated using a band-elimination filter (central frequency: 400 Hz, band width: 1/3 octave). In the LPF mode, only the signal with a frequency less than the third-harmonic frequency was passed using a low-pass filter (cut-off frequency: 1200 Hz, -24 ± 2 dB/octave). The RMS granularity was obtained by calculating standard deviations of the pixel values in the MPI image without MNPs, whereas average MPI values were obtained by drawing a circular region of interest with a diameter of 6 mm on the MPI image of the cylindrical tube phantom. Results: When using the filtered back-projection (FBP) method with a ramp filter for image reconstruction, the RMS granularity and correlation coefficient decreased in the order of THRU, BPF, BEF, and LPF. In the BPF mode, however, some artifacts were observed. When using the maximum likelihood-expectation maximization (ML-EM) algorithm with an iteration number of 15, the correlation coefficient decreased in the order of THRU, BPF, BEF, and LPF, whereas the RMS granularity did not largely depend on the filter mode and was significantly (p < 0.05) lower than that for the FBP method for all the filter modes. Conclusion: The BEF mode is adequate for the FBP method in projection-based MPI, whereas THRU is a best option in use of the ML-EM algorithm.

Item Type: Article
Subjects: STM One > Medical Science
Depositing User: Unnamed user with email support@stmone.org
Date Deposited: 28 Mar 2023 12:35
Last Modified: 25 May 2024 09:01
URI: http://publications.openuniversitystm.com/id/eprint/590

Actions (login required)

View Item
View Item