Dermatomal Somatosensory Evoked Potentials: An Indicator of Improvement of Breast Sensibility after Reduction Mammaplasty

Abu-Hegazy, Mohammad and Gabr, Wael and Ismail, Hossam El-Din A. and Khalil, Ahmad A. (2016) Dermatomal Somatosensory Evoked Potentials: An Indicator of Improvement of Breast Sensibility after Reduction Mammaplasty. Neuroscience and Medicine, 07 (03). pp. 106-113. ISSN 2158-2912

[thumbnail of NM_2016083115181211.pdf] Text
NM_2016083115181211.pdf - Published Version

Download (1MB)

Abstract

Introduction: Many women think about reduction mammaplasty for different reasons. The effect of surgery on the beast sensibility is one of the greatest concerns after reconstructive reductive breast surgery through its affect on patient’s social life and psychological health. The dermatomal somatosensory evoked potential (D-SEP) is a new method to quantitatively evaluate breast sensibility. Patients and Methods: Twenty-five women enrolled in this study presenting with breast enlargement, underwent mammary reduction by using the inferior pyramidal breast reduction technique using the same operative technique described by Robbins with some modifications. All D-SEP amplitudes and latencies were calculated preoperatively and then were reassessed six and twelve months post-surgery in each breast. Result: The results revealed that there is a significant difference in the D-SEP latency pre- and post-operatively. The statistically significant decrease in latency and the breast size demonstrated indicates that the sensibility improved after breast reduction surgery both at six and twelve months. There is also a significant increase in the D-SEP amplitude pre- and post-operatively. The negative and statistically significant increase in amplitude with the decrease in breast size demonstrated indicates that the sensibility improved after breast reduction surgery both at six and twelve months. Conclusion: This study concluded that breast sensibility will improve after breast reduction as indicated by significant reduction of D-SEP latencies and increase of its amplitudes. Our results confirm an inverse relationship between breast size and sensibility, with improvement in sensibility after breast reduction.

Item Type: Article
Subjects: STM One > Medical Science
Depositing User: Unnamed user with email support@stmone.org
Date Deposited: 21 Jan 2023 06:40
Last Modified: 11 Jul 2024 09:34
URI: http://publications.openuniversitystm.com/id/eprint/121

Actions (login required)

View Item
View Item